Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add filters








Language
Year range
1.
Chinese Journal of Radiological Health ; (6): 532-537, 2023.
Article in Chinese | WPRIM | ID: wpr-1003559

ABSTRACT

Objective To analyze the eye lens equivalent dose levels of doctors during interventional cardiology procedures and identify related influential factors. Methods Twenty interventional specialists were selected from a cardiovascular specialty hospital. The cumulative equivalent doses to their eye lens during operations were monitored, and equipment-related parameters (fluoroscopy time, dose area product value [DAP], and entrance skin dose[ESD]), operation types, and operators’ positions were recorded. Results The annual equivalent doses to the eye lens of seven doctors exceeded 20 mSv. There was a linear correlation between the weekly number of operations and the equivalent dose to the eye lens (R2 = 0.457, P = 0.001). The mean eye lens equivalent dose per operation was 17.1 μSv, showing linear correlations with fluoroscopy time, DAP values, and ESD values (R2 = 0.427, 0.206, and 0.237, respectively, P < 0.05). The fluoroscopy time, DAP value, ESD value, and eye lens equivalent dose during percutaneous coronary intervention (PCI) were significantly higher than those during coronary angiography (t = −3.226, −3.108, −3.061, and −2.667, respectively, P < 0.03). Conclusion The annual equivalent doses to the eye lens are relatively high in interventional radiologists, some of whom may have values higher than the latest dose limit (20 mSv) suggested by the International Commission on Radiological Protection. Attention should be paid to operators performing PCI, and the workload optimization is necessary in practical operations to avoid unnecessary fluoroscopy time and reduce the eye lens doses of the operators.

2.
Journal of Public Health and Preventive Medicine ; (6): 67-71, 2021.
Article in Chinese | WPRIM | ID: wpr-862733

ABSTRACT

Objective To investigate the correlation between smoking, white blood cell counts, and serum bilirubin levels in male radiation workers, and to explore the role of systemic inflammatory response in the changes of serum bilirubin level induced by smoking. Methods Occupational health examination data of 1 320 male radiation workers in a medical institution was collected. Linear regression analysis method was used to analyze the correlations between smoking and white blood cell counts, between smoking and serum bilirubin levels, and between white blood cell counts and serum bilirubin levels. Results There was a significant positive correlation between smoking and white blood cell counts (P 0.05). By dividing white blood cell counts into two groups, an inverse correlation was found between smoking and serum bilirubin levels in the high white blood cell count group (P < 0.05). Conclusion Serum bilirubin may be an effective indicator of early health damage caused by smoking in male radiation workers. Smoking may induce inflammatory reaction, thus deplete serum bilirubin and cause its levels to drop.

3.
Chinese Journal of Radiological Medicine and Protection ; (12): 338-342, 2020.
Article in Chinese | WPRIM | ID: wpr-868454

ABSTRACT

Objective:To investigate the safety and protection level of radiological treatment in the CT modules in the makeshift hosptials in Wuhan during the prevention and treatment of COVID-19 cases.Methods:The layout of the CT modules in makeshift hospitals, radiological protection facilities and personal protective equipment were investigated. Based on the national standards, the CT dose index was estimated and the radiological protection level at the CT modules were measured.Results:The layout of the CT modules in makeshift hospitals is reasonable, with well-equipped radiological protection facilities. Of 23 CT modules, 20 were up to standards with acceptability of 87.0%. The other three were unqualified each with 1 detection points having values in excess of the national standards. Which, after being modified immediately reached the national standards. In addition, CT dose index for 7 CT modules were estimated, with CTDI W within ±7.5%. Conclusions:The CT modules in Wuhan meet the requirements of radiological safety and protection during the prevention and treatment of COVID-19 cases.

4.
Chinese Journal of Radiological Medicine and Protection ; (12): 253-258, 2020.
Article in Chinese | WPRIM | ID: wpr-868438

ABSTRACT

Objective:To survey and supervise the risk of infection control and radiation safety in the radiological diagnostic workplace for COVID-19, and provide data support for the safety protection of radiographers and related staff.Methods:4 emergency hospitals for COVID-19 including 2 makeshift hospitals, module hospital and brick pattern hospital in Hubei province were performed for testing and evaluation of imaging performance and radiological protection for the 8 new installed CT scanners and places according to the national standards of WS 519-2019 and GBZ 130-2013. The infection control safety factors such as the layout of the equipment room were monitored and investigated. Two COVID-19 designated hospitals including general hospital and infectious disease specialized hospital were selected to carry out field investigation and sampling of environmental biological samples for 4 CT rooms. Then the samples were detected for the nucleic acid of novel coronavirus. The results of radiodiagnostic workplace overall arrangement, infection prevention and the nucleic acid testing were analyzed, and the biological safety reliability and risk point were evaluated.Results:The indicators of imaging performance and radiation protection for 8 CT scanners in emergency hospitals could meet the requirements of national standards.Each of 2 makeshift hospitals had 3 CT rooms with the area of 38.8 m 2 and 4 mm Pb equivalent thickness of protective shielding. The CT rooms in module hospital and brick pattern hospital were 20.0 m 2, and 35.8 m 2 in areas, with 4 mm Pb equivalent and 3 mm Pb equivalent thickness of protection shielding, respectively. The 8 radiological diagnostic workplaces of the emergency hospitals were designed and constructed based on " three zones with two passage ways" . The result of the nucleic acid test indicated that the positive samples were found at the multiple sites such as scanning bed, internal of gantry and ground touched by patients in CT scanning room. The areas such as console panel and ground were risked of pollution by the virus infected hands and feet of radiographers. In addition, the similar positive samples were found in the areas in scanning room with no touch of patients, such as observation window and air outlet. Conclusions:8 CT scanners and rooms in 4 emergency hospitals basically meet the requirements of imaging performance and radiation protection. The disinfection of COVID-19 radiodiagnostic workplace should be standardized.

5.
Journal of Public Health and Preventive Medicine ; (6): 135-137, 2020.
Article in Chinese | WPRIM | ID: wpr-821217

ABSTRACT

Objective To investigate the effect of low dose ionizing radiation on blood pressure of radiation workers. Methods A total of 219 medical staff from a hospital in Wuhan were enrolled in the present study. Of them, 115 radiation workers were included in the low-dose ionizing radiation exposure group, the remaining 104 non-radiation workers were used as the control group. The blood pressure of the two groups was measured. The individual annual doses of the exposed group were collected. The independent sample t test was used to compare the blood pressure of the two groups. The linear regression model was used to analyze the relationship between the annual dose and blood pressure of the exposed group, and the logistic regression analysis method was used to analyze the relationship between hypertension and the annual dose of the exposed group. Results It was found that the mean blood pressure of the exposed group was significantly higher than that of the control group, and the difference was statistically significant (P<0.05). Linear regression analysis found that there was no significant correlation between the annual dose of the exposed group and blood pressure. Logistic regression analysis revealed that in the exposed group, women had a higher risk of hypertension than men, while the individual annual dose was not significantly associated with hypertension. Conclusion Women in radiation work were at higher risk than men, and low-dose ionizing radiation was not significantly associated with changes in blood pressure in radiation workers.

6.
Journal of Practical Radiology ; (12)2000.
Article in Chinese | WPRIM | ID: wpr-547026

ABSTRACT

Objective To explore the clinical features and CT characteristics of invasive pulmonary aspergillosis(IPA) in children with acute leukemia.Methods CT scanning of chest was performed in 13 cases with IPA proved clinically and sputum culture in children with acute leukemia.All cases followed up by CT 4 to 10 times.The clinical features and CT findings were analyzed retrospectively.Results The early CT findings included single nodule in 2 cases,multi-nodular shadow in 10 case and sub-pleural wedge-shaped consolidation in 5 cases,of these 5 cases,4 accompanied multi-nodules.Halo sign around the nodules in 9 cases.The follow-up CT showed air crescent sign or cavity in 11 cases,halo sign around the nodules in 7 cases and around cavity in 2 cases.Conclusion IPA has some characteristic manifestations on CT.CT is of important value in observing the evolution and evaluating the prognosis for the patients with IPA.

SELECTION OF CITATIONS
SEARCH DETAIL